Configuring IntelliSight Devices: Camera Setup

Easy Setup

The Easy Setup section provides a quick way to set conditions and corresponding actions for each zone. When a zone is added to the configuration, the vehicle presence condition is automatically selected and the display action is set to green when a vehicle is detected and gray when no vehicle is present in the zone. When using the Easy Setup you must select an output that is to be sent to the controller when vehicle/bicycle/pedestrian detection takes place. NOTE: If an output is not to be assoicated with a condition, the Zones Explorer or Actions Explorer section must be used instead of Easy Setup. To set conditions and actions using Easy Setup, do the following.
  • Select a zone, either in the image or by clicking the zone description in the Easy Setup section. A presence condition is automatically selected for each defined zone.
  • To assign the Bicycle Presence condition to the zone, select the Bicycle check box. A bicycle icon appears in the lane.
  • To define what color the zone/bicycle icon is to be outlined in on the video, click a color block and select a color. Click eleswhere on the screen to close the color selection pop-up.
The first block defines the display color when a vehicle/bicycle/ pedestrian is detected (present in the zone) and the second block defines the color when the zone is empty (no detection). NOTE: It is recommended that red not be used, as this is the color used by the system to indicate when the sensor is in failsafe mode.
4. In the field to the right of the color blocks, select the output that will be sent to the controller when detection takes place.
  • If the output selections do not appear when the box is clicked, de-select then reselect the condition check box.
  • An output must be selected for each active condition. If an output is not to be associated with a condition or if more than one output is to be associated with a condition, the Zones Explorer or Actions Explorer section must be used instead of Easy Setup. Multiple outputs for a single condition do not appear on the Easy Setup screen.
  • To change the initial state of the output or to set the output options, use the Actions Explorer.
5. To change the zone description, highlight it and type a new description. For additional information about changing descriptions, see Changing Zone, Condition, and Action Descriptions. 6. When all conditions and actions have been defined, click Apply Changes. All assigned outputs are set to "call" (ON), and stay in "call" until detection sets the output OFF or for a maximum of five minutes, whichever occurs first. After all zones are defined and configured, it is recommended that the configuration be archived (see Saving an Archive File).
Version 4.3.1 - Copyright © 2024, Image Sensing Systems, Inc. All rights reserved.

We use cookies to enable essential functionality on our website, and analyze website traffic. By clicking Accept you consent to our use of cookies. Read about how we use cookies.

Your Cookie Settings

We use cookies to enable essential functionality on our website, and analyze website traffic. Read about how we use cookies.

Cookie Categories
Essential

These cookies are strictly necessary to provide you with services available through our websites. You cannot refuse these cookies without impacting how our websites function. You can block or delete them by changing your browser settings, as described under the heading "Managing cookies" in the Privacy and Cookies Policy.

Analytics

These cookies collect information that is used in aggregate form to help us understand how our websites are being used or how effective our marketing campaigns are.