Configuring IntelliSight Devices: Zones Explorer

Assigning a Pulse Condition

The Pulse condition is used to send an output to the controller every time a vehicle exits the defined zone. In a system that utilizes a gap timer to extend on green, the activated (pulsed) output would reset the timer. In a system that utilizes counts, each exiting vehicle causes a pulse. A typical use would be in an advance zone to determine whether the green phase should be extended. NOTE: A single zone covering multiple lanes is not recommended when using Pulse outputs.
  • In the Zone Explorer section, click the plus sign (+) to the right of the zone description and select Pulse. A Set Output action is automatically added to the Phase color condition.
2. Use the drop-down menu to select an output to be sent to the controller every time a vehicle exits the zone. To change the initial state of the output or to set the output options, use the Action Explorer. 3. When all conditions and actions have been defined, click APPLY CHANGES.
Version 4.5.0 - Copyright © 2025, Image Sensing Systems, Inc. All rights reserved.

We use cookies to enable essential functionality on our website, and analyze website traffic. By clicking Accept you consent to our use of cookies. Read about how we use cookies.

Your Cookie Settings

We use cookies to enable essential functionality on our website, and analyze website traffic. Read about how we use cookies.

Cookie Categories
Essential

These cookies are strictly necessary to provide you with services available through our websites. You cannot refuse these cookies without impacting how our websites function. You can block or delete them by changing your browser settings, as described under the heading "Managing cookies" in the Privacy and Cookies Policy.

Analytics

These cookies collect information that is used in aggregate form to help us understand how our websites are being used or how effective our marketing campaigns are.